Click here to

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

3 | A | B | C | D | E | F | G | H | I | K | L | M | N | O | P | Q | R | S | T | U | V | X | show all

Keywords: Calibration
PO-GePV-T-2Independent Determination of Absorbed Dose to Water Depth-Dose Curves for Ru-106 Ophthalmic Plaques Traceable to the Primary Standards of External Beam Radiotherapy
V Kaveckyte1,2*, S Dahlander2, A Carlsson Tedgren1,2, (1) Department of Health, Medicine and Caring Sciences, Linkoping University, SE-58185 Linkoping, Sweden (2) Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-17176 Stockholm, Sweden
PO-GePV-T-39Real-Time in Vivo Dosimetry for Electron Beam Therapy Using Amorphous Silicon Based Flexible Thin Film Combined with Scintillating Powder
S Jeong*, Y Kwon, S Park, D Shin, Y Lim, J Jeong, H Kim, W Cheon, S Lee, National Cancer Center, Goyang-si,, 41KR,
PO-GePV-T-89Clinical Evaluation of Optically Stimulated Luminescence Dosimeters Dose Accuracy in Intensity Modulated Proton Therapy
J Yu*, A Wroe, A Gutierrez, Miami Cancer Institute, Baptist Health South Florida, Miami, FL
PO-GePV-T-179EBT3 Film Calibration Using Deep Learning with Keras Functional API
L Chang*, I-Shou University, Kaohsiung, KHQTW,
SU-IePD-TRACK 6-7Correction Factors for a Planar Windowless Extrapolation Chamber Measuring Surface Absorbed Dose to Water From An Unsealed Thin-Film Alpha-Emitting Radionuclide
A Khan*, W Culberson, L DeWerd, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI
TH-A-TRACK 6-4Assessment of the Dependence of the Field Shape On Calibration Coefficients in Dose Area Product (DAP) for Small Field Sizes
J JURCZAK1*, B Rapp1, S Dufreneix2, F Delaunay1, J Gouriou1, J-M Bordy1, (1) Universite Paris-Saclay, CEA, List, Laboratoire National Henri Becquerel (LNE-LNHB), F-91120 Palaiseau, France, (2) Institut de Cancerologie de l'Ouest - Site Paul Papin (ICO Angers) - Departement de physique medicale - 15 rue Boquel, 49055 Angers Cedex 02, France
TH-IePD-TRACK 1-7Spctrally Neutral CT Calibration
R Jennings*, Retired, Olney, MD
TU-F-TRACK 5-7A Pyroelectric Calorimeter with Electrometer Readout for the Absolute Dosimetry of FLASH Radiation: Proof of Principle
J Renaud*, B Muir, National Research Council, Ottawa, ON
WE-IePD-TRACK 1-3Online Bayesian Geometric Calibration of CBCT Systems
O Dillon*, T Reynolds, R O'Brien, University of Sydney, Sydney, NSWAU,
WE-IePD-TRACK 2-3Independent Verification of a Ge-68/Ga-68 Well Counter Accuracy Source Activity Mis-Calibration
W Erwin*, D Mitchell, UT MD Anderson Cancer Center, Houston, TX

Share: