PO-GePV-T-94 | Novel Collimator for High-Throughput Proton FLASH-RT Murine Hemithorax Irradiations S Mossahebi, Y Poirier*, A Gerry, C Repetto, Z Vujaskovic, I Jackson, A Sawant, University of Maryland School of Medicine, Baltimore, MD |
PO-GePV-T-145 | Validation of Radiochromic.com Gamma Analysis Software I Mendez1*, J Rovira Escutia2, B Casar1, (1) Institute of Oncology Ljubljana, Ljubljana, 061, SI, (2) Centro Nacional De Dosimetria. Ingesa, Valencia, ES |
PO-GePV-T-149 | A Custom-Made Cassette for In-Water Film Dose Measurements and Quality Assurance of Cs-137 Blood Irradiators H Moktan*, S Jayarathna, R Tailor, S H Cho, UT MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-179 | EBT3 Film Calibration Using Deep Learning with Keras Functional API L Chang*, I-Shou University, Kaohsiung, KHQTW, |
PO-GePV-T-184 | Development of a User-Friendly Correction Method for the Lateral Response Artifact From Flatbed Scanners in Radiochromic Film Dosimetry G Guyer*, R Kueng, A Joosten, M K Fix, P Manser, S Mueller, Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University Of Bern, Bern, CH |
PO-GePV-T-217 | A Study of Surface Dosimetry for Whole Breast Irradiation Geometry Using EBT3 Gafchromic Film and Monte Carlo Simulation S Su1*, E Carpentier2, C Duzenli1,2, (1) British Columbia Cancer Agency, Vancouver, BC, CA, (2) University of British Columbia, Vancouver, BC, CA |
PO-GePV-T-248 | Dosimetric Study for Spine SRT Plans with Carbon Fiber Stabilization Devices H Lee*, J D. Palmer, A S. Ayan, Ohio State Univ, Columbus, OH |
PO-GePV-T-349 | Thresholding Gamma Analysis On SRS Anthropomorphic Phantoms A Molineu*, L Acuna Scafati, S Kry, UT MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-351 | Evaluation of Delivery Quality Assurance of Cyberknife Stereotactic Radiosurgery J Li*, X Zhang, H Zhuang, R Yang, Peking University Third Hospital, Beijing, BeijingCN, |
SU-IePD-TRACK 5-7 | Novel Plastic Scintillator for Online Dosimetry in Electron FLASH-RT Y Poirier1*, J Xu1, A Ahmady1, S Mossahebi1, H Zhang1, F Therriault-Proulx2, A Sawant1, (1) University of Maryland School of Medicine, Baltimore, MD, (2) MedScint, Quebec City, QC |
SU-IePD-TRACK 6-2 | Evaluating Dosimetric Accuracy of EBT3 Radiochromic Film Calibration Using 6 MV Photon Beam in HDR Ir-192 Dose Measurement L Huang*, J Chang, H Gaballa, Northwell Health, Lake Success, NY |
TH-A-TRACK 6-2 | An Evaluation of the Use of EBT-XD Film for SRS/SBRT Commissioning of Unity MR-Linac System S Lim*, N Tyagi, E Subashi, J Liang, M Chan, Memorial Sloan Kettering Cancer Center, New York, NY |
TH-A-TRACK 6-6 | Geometric and Dosimetric Verification for a Novel Stereotactic Radiosurgery System: ZAP-X Y Niu*, Y Yuan, A Rashid, D Pang, Department of Radiation Medicine, MedStar Georgetown University Hospital, Washington, DC |
TH-IePD-TRACK 5-1 | Evaluation of a Novel Film Dosimetry System: Orthochromic OC-1 Film S Lim*, G Tang, Memorial Sloan-Kettering Cancer Center, New York, NY |
TH-IePD-TRACK 5-7 | In Situ Radiochromic Film Dosimetry Using Portable Spectrophotometer S Jung*, J Cho, J Han, J Kim, J Park, C Choi, J Son, J Kim, |
TU-IePD-TRACK 5-2 | Characteristics Evaluation of Contact Lens in Vivo Ocular Dosimeter for Proton Therapy J Son1*, J Han2, J Jeong3, S Jung3, C Choi1, J Park1, J Kim1, (1) Department of Radiation Oncology, Seoul National University Hospital, Seoul, KR, (2) Biomedical Research Institute, Seoul National University Hospital, Seoul, KR,(3) Proton therapy center, National Cancer Center, Goyang-si Gyeonggi-do, KR, |