Keywords: scintillators
MO-IePD-TRACK 1-3A Novel Integrating Proton Radiography System with a Monolithic Scintillator Detector
C Darne1*, D Robertson2, F Alsanea3, I Tendler4, L Perles5, C Collins-Fekete6, S Beddar7, (1) UT MD Anderson Cancer Center, Houston, TX, (2) Mayo Clinic Arizona, Phoenix, AZ, (3) UT MD Anderson Cancer Center, Houston, TX, (4) UT MD Anderson Cancer Center, Houston, TX, (5) UT MD Anderson Cancer Center, Houston, TX, (6) University College London, London, GB, (7) UT MD Anderson Cancer Center, Houston, TX
MO-IePD-TRACK 6-1Quantifying of the Afterglow Effect From a Chromium-Doped Alumina Scintillator Following Proton Irradiation
T Geoghegan1*, K Patwardhan1, B Smith1, R Flynn1, J Yu2, A Gutierrez2, D Hyer1, (1) University of Iowa Hospital and Clinics, Iowa City, IA, (2) Miami Cancer Institute, Baptist Health South Florida, Miami, FL
MO-IePD-TRACK 6-2Investigations of a Novel HyperscintTM Plastic Scintillator Detector and Hyperspectral Analysis Approach in a 74 MeV Proton Beam
C Duzenli1*, C Hoehr2, C Belanger-champagne2, C Penner3, V Strgar5, (1) British Columbia Cancer Agency, Vancouver, BC, CA, (2) TRIUMF, Vancouver, BC, CA, (3) University of British Columbia, Bc, CA
MO-IePD-TRACK 6-3Development of a Novel Hybrid Scintillation-Cerenkov Detector for Simultaneous Dose and Irradiation Angle Measurements
E Jean1,2*, S Lambert-girard3, F Therriault-Proulx3, L Beaulieu1, (1) CHU de Quebec - Universite Laval, Quebec, QC, (2) CHAUR, Trois-Rivieres, QC, (3) Medscint Inc., Quebec, QC
MO-IePD-TRACK 6-4Output Constancy of the W2 Scintillator in Flattening Filter Free Fields in a Medical Linac
S Thrower1*, S Holmes2, S Prajapati1, E Schueler1, S Beddar1, (1) UT MD Anderson Cancer Center, Houston, TX, (2) Standard Imaging, Inc., Middleton, WI
PO-GePV-T-344A Comparison of Field Output Corrections Factors for a Diode Detector Among Various Measurement Setups and Among Various Energies for Stereotactic Cones
Y Lee1*, Y Kim2, (1) Miami Cancer Institute, Miami, FL, (2) Duke University, Durham, NC
SU-IePD-TRACK 5-7Novel Plastic Scintillator for Online Dosimetry in Electron FLASH-RT
Y Poirier1*, J Xu1, A Ahmady1, S Mossahebi1, H Zhang1, F Therriault-Proulx2, A Sawant1, (1) University of Maryland School of Medicine, Baltimore, MD, (2) MedScint, Quebec City, QC
SU-IePD-TRACK 6-1Monte Carlo Characterization of High Atomic Number Inorganic Scintillators for in Vivo Dosimetry in Ir-192 Brachytherapy
V Kaveckyte1,2*, E B Joergensen3,4, J G Johansen4, A Carlsson Tedgren1,2 (1) Department of Health, Medicine and Caring Sciences, Linkoping University, SE-58185 Linkoping, Sweden (2) Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, SE-17176 Stockholm, Sweden (3) Aarhus University, Health Graduate School, DK-8000 Aarhus, Denmark (4) Department of Oncology, Aarhus University Hospital, DK-8200 Aarhus, Denmark
TH-C-TRACK 6-7Measurement of Secondary Neutron Spectrum with He4 Fast Neutron Detector
Y Liang1, S Gokhale1, J Nimmagadda1, E Kryck2, A Enqvist1, S Samant3*, (1) Nuclear Engineering Program, University of Florida, Gainesville (2) uclear Engineering Program, University of Florida, Gainesville (3) University of Florida, Dept of Radiation Oncology, Gainesville, FL 32610-0385, United States
TU-EF-TRACK 4-7Spatiotemporal Dose Characterization of An Electron FLASH Beam From a LINAC Using Radioluminescence and Cherenkov Imaging
M Rahman1*, M Ashraf1, R Zhang1,2,3, D Gladstone1,2,3, X Cao1, B Williams1,2,3, J Hoopes1,2,3,4, B Pogue1,3,4, P Bruza1, (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College, Hanover, NH, (3) Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, (4) Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, NH
TU-F-TRACK 5-5Pulse Resolved Beam Characterization and Feedback for FLASH-RT Using Radioluminescent Dosimeters
M Ashraf1*, M Rahman1, R Zhang2, B Williams2, J Hoopes1,D Gladstone2, B Pogue1, P Bruza 1(1) Dartmouth College, Thayer Engineering, Hanover, NH,(2) Dartmouth-Hitchcock Med. Ctr., Lebanon, NH
WE-IePD-TRACK 6-6Miniaturized Scintillator Dosimeter for Small Field Dosimetry
M Gonod1*, C Chacon Avila2, M Suarez2, J Crouzilles3, S Laskri3, J Vinchant3, L Aubignac1, T Grosjean2, (1) Centre Georges-Francois Leclerc, Dijon, 21, FR, (2) FEMTO-ST Institute - Optics Departement - UMR 6174 - University of Bourgogne Franche-Comte, Besancon, Doubs,25(3) SEDI-ATI Fibres Optiques,Evry-Courcouronnes,91