DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
Taxonomy: TH- External Beam- Photons: cyberknife
PO-GePV-P-36 | CyberKnife 0-View (xSight Spine) Tracking for Lung Tumors: Is It Safe at Distances Greater Than 5cm? M Curry*, C Busselberg, M White, J Conlon, MercyOne Des Moines, Grimes, IA |
PO-GePV-T-282 | Clinical Impact of the Dose Calculation Engine for Vestibular Schwannoma Treatments On Cyberknife E Ali*, E Vandervoort, The Ottawa Hospital Cancer Centre, Ottawa, Ontario, Canada |
PO-GePV-T-334 | Pre-Treatment 4DCT Fiducial Marker Combination Selection for Robotic Lung SBRT W Belcher*, A Ju, J Jung, East Carolina Univ, Greenville, NC |
PO-GePV-T-335 | Prediction of Fiducial Marker Positions in Robotic SBRT Using 4D-CTs at Different Treatment Dates J Jung1*, W Belcher1, K Patel1, E Patel1, K Yang2, S Sharma2, A Ju2, (1) East Carolina Univ, Greenville, NC, (2) Medical School of East Carolina Univ, Greenville, NC |
PO-GePV-T-337 | Effect of Target Positioning Error On Tumor Control Probability in Stereotactic Radiosurgery for Metastatic Brain Tumors Using the CyberKnife M6 T Takizawa1,2*, S Tanabe3, H Nakano3, S Utsunomiya4, M Sakai3, K Maruyama1, S Takeuchi5, T Nakano2, A Ohta3, M Kaidu2, H Ishikawa2, K Onda5, (1) Department of Radiation Oncology, Niigata Neurosurgical Hospital, Niigata, JP, (2) Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, Niigata, JP, (3) Department of Radiation Oncology, Niigata University Medical and Dental Hospital, Niigata, JP, (4) Department of Radiological Technology, Niigata University Graduate School of Health Sciences, Niigata, JP, (5) Department of Neurosurgery, Niigata Neurosurgical Hospital, Niigata, JP |
PO-GePV-T-351 | Evaluation of Delivery Quality Assurance of Cyberknife Stereotactic Radiosurgery J Li*, X Zhang, H Zhuang, R Yang, Peking University Third Hospital, Beijing, BeijingCN, |
PO-GePV-T-379 | Dosimetric Comparison of ZAP-X and CyberKnife Stereotactic Radiosurgery for Single Brain Metastasis J Wang1, L Pan2, B Qu1, M Bodduluri3, X Dai1, Z Ju1, C Wang1, J Bai1, S Xu1*, (1) Department of Radiation Oncology, the First Medical Center of PLA General Hospital, Beijing, BJ, CN, (2) Department of Neurosurgery, the First Medical Center of PLA General Hospital. Beijing, BJ, CN, 3)Zap Surgical Systems, Inc. San Carlos, CA, USA, |
PO-GePV-T-405 | Comparison of Ray Tracing and Monte Carlo Algorithms for Spine Lesions Treated with CyberKnife J Li*, X Zhang, Y Pan, H Zhuang, R Yang, |
TH-A-TRACK 6-7 | Quality Assurance of CyberKnife Small Radiation Fields Using High-Resolution Scanning Diode Detector K Yang1*, S Sharma1, A Ju1, (1) East Carolina University, Greenville, NC |
TH-E-TRACK 6-7 | Using Deep Learning Framework (pytorch) for Circular Cone Treatment Planning of CyberKnife System B Liang1*, R Wei1, Y Li2, B Liu3,4, S Xu5, F Zhou3,4, Q Wu6, J Dai1, (1) National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, Beijing, CN, (2) Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangzhou, Guangdong, CN, (3) Image Processing Center, Beihang University, Beijing, CN, (4) Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, CN, (5) Chinese PLA General Hospital, Beijing, Beijing, CN, (6) Duke University Medical Center, Durham, NC |
TH-F-TRACK 6-7 | Modeling Dosimetric Impact of Treatment Delivery Errors in Robotic Radiosurgery: Experimental Validation and Applications M Liu1,2*, J E Cygler1,2,3, E Vandervoort1,2,3, (1) The Ottawa Hospital Cancer Centre, Ottawa, ON, Canada (2) Carleton University, Ottawa, ON, Canada (3) University of Ottawa, Ottawa, ON, Canada |