DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
PO-GePV-I-52 | Infuence of Abnormal Right Coronary Artery Originating From the Left Coronary Sinus in Hemodynamic Environment H Zhao*, M Cong, J Qiu, S Sun, The Second Affliated Hospital of Shandong First Medical University, Tai'an, Shandong,CN |
TH-A-206-5 | Towards Finding the Right Liver Vasculature Model for Estimating Dose to Circulating Blood During Radiotherapy in Hepatocellular Carcinoma Patients S Xing1,2*, C Correa Alfonso3, J Shin4, J Pursley1,2, N Depauw1,2, L McCullum1,2, S Domal3, J Withrow3, W Bolch3, C Grassberger1,2, H Paganetti1,2, (1) Harvard Medical School, Boston, MA, (2) Massachusetts General Hospital, Boston, MA, (3) University of Florida, Gainesville, FL, (4)National Cancer Institute, Rockville, MD |
TH-A-207-3 | Effect of Realistic Pulsatile Flow Versus Constant Flow On Contrast Visualization for 1000 Fps High-Speed Angiography (HSA) in Patient-Specific 3D-Printed Models E Vanderbilt*, A Shields, X Wu, S Setlur Nagesh, D Bednarek, S Rudin, University at Buffalo (SUNY) School of Medicine, Buffalo, NY |
TH-B-207-1 | Evaluation of Shear Forces Within Stenotic Vessel Models Using 1000 Fps X-Ray Particle Image Velocimetry (X-PIV) A Shields*, D Bednarek, S Rudin, University at Buffalo (SUNY) School of Medicine, Buffalo, NY |
TH-C-201-1 | 1000 Fps High Speed Angiography (HSA) of Contrast Injections in An In-Vitro Model with Pulsatile Flow Using Simulated Cardiac Gating Techniques X Wu*, S Setlur Nagesh, E Vanderbilt, A Shields, C Ionita, D Bednarek, S Rudin, SUNY Buffalo, Buffalo, NY |
TH-C-201-4 | BEST IN PHYSICS (IMAGING): Implementation of 1000 Fps CdTe Photon-Counting Detectors (PCD’s) for Simultaneous Biplane High-Speed Angiography (HSA) E Vanderbilt*, X Wu, A Shields, S Setlur Nagesh, D Bednarek, S Rudin, University at Buffalo (SUNY) School of Medicine, Buffalo, NY |
TH-D-BRC-3 | Dynamic Brain Blood Flow Modeling Using Detailed Vasculature to Investigate Lymphocyte Depletion During External Beam Radiotherapy L McCullum1*, S Xing1, J Shin2, C Beekman1, C Correa Alfonso3, S Domal3, J Withrow3, W Bolch3, H Shih1, H Paganetti1, C Grassberger1, (1) Massachusetts General Hospital / Harvard Medical School, Boston, MA (2) National Cancer Institute, Bethesda, MD, (3) University of Florida, Gainesville, FL |
TU-D1000-IePD-F9-6 | Image Corrections for a 1000 Fps High-Speed Angiography (HSA) Photon Counting Detector (PCD) System X Wu*, S Setlur Nagesh, A Shields, E Vanderbilt, C Ionita, D Bednarek, S Rudin, SUNY Buffalo, Buffalo, NY |