PO-GePV-M-150Feasibility of Using the Planning CT (pCT) Electron Density Calibration Curve for Prostate Cancer Adaptive Planning Based On Daily Cone-Beam CT
P Shukla*, D Mynampati, P Brodin, A Lukaj, R Yaparpalvi, A Basavatia, W Tome, Montefiore Medical Center, Bronx, NY
PO-GePV-M-315Utilizing a 3D-Printed Chamber Holder to Improve Setup Uncertainty in the Calibration of a Superficial Radiotherapy Machine
L Ku, B Casto, J Ying*, Salem Hospital, Salem, OR
PO-GePV-T-40Novel Film Calibration Method Directly Using Low Energy Brachytherapy Sources with a Custom Phantom
C Oare, A Alshreef*, C Ferreira, University of Minnesota, Minneapolis, MN
PO-GePV-T-337Extending the Lifetime of Optically Stimulated Luminescent Dosimeters for Use in Output Checks at IROC- Houston
H Scott1*, P Alvarez1, R Sun1, R Howell1, A Riegel2, S Kry1, (1) UT MD Anderson Cancer Center, Houston, TX, (2) Northwell Health, Lake Success, NY
SU-H300-IePD-F8-5Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
P Rodesch*, D Richtsmeier, L Zalavari, M Bazalova-Carter, University of Victoria, Victoria, BCCA,
TU-F115-IePD-F4-3Fading Correction for Calibration of a Novel 2D OSL-Film Dosimeter
M Caprioli1*, M De Saint-hubert2, L De Freitas Nascimento3, R De Roover4, L Delombaerde5, S Galvez Febles6, K Himschoot7, P Leblans8, B Van Der Heyden9, D Vandenbroucke10, W Crijns11, (1) KU Leuven, Brussels, VBR, BE, (2) Belgian Nuclear Research Centre (SCK CEN), Mol, ,BE, (3) Belgian Nuclear Research Centre (SCK CEN), Mol, ,BE, (4) UZ Leuven, Leuven, ,BE, (5) UZ Leuven, Leuven, ,BE, (6) Belgian Nuclear Research Centre (SCK CEN), Mol, ,BE, (7) Agfa N.V., Mortsel, ,BE, (8) Agfa N.V., Mortsel, ,BE, (9) Belgian Nuclear Research Centre (SCK CEN), Mol, ,BE, (10) Agfa N.V., Mortsel, ,BE, (11) UZ Leuven, Leuven, VBR, BE
WE-C1000-IePD-F4-2A Comparison of AAPM’s TG-51 and IAEA’s TRS-483 Protocols for Clinical Reference Dosimetry of the CyberKnife M6 
J Duchaine1,2*, D Markel3, J-L Ley3, D Béliveau-Nadeau3, H Bouchard1,2,3, (1) Département de physique de l'Université de Montréal, Montréal, QC, CA, (2) Centre de recherche du Centre hospitalier de l'Université de Montréal, QC, CA, (3) Centre hospitalier de l'Université de Montréal, QC, CA