MO-C930-IePD-F6-2 | Towards Quantitative In-Tumor Dosimetry Using XACT L Sun1, G Gonzalez2, P Pandey3*, S Wang4, Y Chen5, L Xiang6, (1) University of California Irvine, Irvine, CA, (2) University of Oklahoma Health Sciences Center, Oklahoma City, OK, (3) University of California, Irvine, ,,(4) University of California, Irvine, Irvine, CA, (5) University of Oklahoma Health Science Center, Oklahoma City, OK, (6) University of California, Irvine, Irvine, CA |
MO-FG-BRB-8 | Pulse to Pulse Cherenkov Imaging In Vivo During FLASH Radiotherapy Tracks Output and Surface Profiles M Rahman1*, M Ashraf1,2, R Zhang1,3,4, X Cao1,5, D Gladstone1,3,4, L Jarvis3,4, J Hoopes1,3,4,6, B Pogue1,4,6,7, P Bruza1, (1) Thayer School of Engineering, Dartmouth College, Hanover, NH, (2) Department of Radiation Oncology, Stanford University, Palo Alto, CA, (3) Department of Medicine, Radiation Oncology, Geisel School of Medicine, Dartmouth College Hanover NH, (4) Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, NH, (5) School of Life Science and Technology, Xidian University, Xian, CN, (6) Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, NH (7) University of Wisconsin-Madison, Madison, WI |
PO-GePV-M-90 | Proton Radiography as a Quality Control Tool for 3D and 4D Thorax Synthetic CTs C Seller Oria1*, A Thummerer1, J Free1, G Guterres Marmitt1, A Meijers2, A Knopf123, J Langendijk1, S Both1, (1) Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands, (2) Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland, (3) Department of Internal Medicine, Center for Integrated Oncology Cologne, University Hospital of Cologne, Cologne, Germany |
PO-GePV-M-312 | One-Stop-Shop for End-To-End Patient-Specific QA: A Glimpse Into the Future M DiMascio1, L Bohorquez2*, (1) Atrium Health, Charlotte, NC, (2) LAP, Boynton Beach, FL |
PO-GePV-T-20 | Miniaturized Scintillator Detector for in Vivo Dosimetry in HDR Brachytherapy M Gonod1, M Suarez2, C CHACON3, J Crouzilles4, S Laskri5, J Vinchant6, T Grosjean7, L Marage8*, (1) Centre Georges-Francois Leclerc, Dijon, 21, FR, (2) FEMTO-ST Institute - University of Bourgogne Franche-Comte, Besancon, ,FR, (3) FEMTO-ST Institute - University of Bourgogne Franche-Comte, Besancon, 25, FR, (4) SEDI-ATI Fibres Optiques, Evry-courcouronnes, ,FR, (5) SEDI-ATI Fibres Optiques, Evry-courcouronnes, FR, (6) SEDI-ATI Fibres Optiques, Evry-courcouronnes, FR, (7) FEMTO-ST Institute - University of Bourgogne Franche-Comte, Besancon, FR, (8) Dijon, 21, FR |
PO-GePV-T-21 | In-Vivo Detection of Strut Deformation in Partial Breast Irradiation M Walls1*, C Ramsey1,2, I Pfeiffer2, (1) University of Tennessee, Knoxville, TN, (2) Thompson Cancer Survival Center, Knoxville, TN |
PO-GePV-T-73 | Commissioning Total Skin Electron Therapy and Monte Carlo Verification of Patient Skin Dose W Nie1*, I Yeo1, K Huynh1, S Tong2, J Fan1, (1) INOVA Schar Cancer Institute, Fairfax, VA, (2) Inova Alexandria Hospital, Alexandria, VA. |
PO-GePV-T-197 | A Clinically Relevant Online Patient QA Solution for Adaptive Radiation Therapy with Daily CT Scans and EPID-Based in Vivo Dosimetry: A Feasible Study On Rectal Cancer L Chen*, J Wang, B Feng, L Yu, j zhao, W Hu, Z Zhang, Fudan University Shanghai Cancer Center, Shanghai, ShanghaiCN, |
PO-GePV-T-217 | EPID-Based 3D In-Vivo Dose Verification Using Deep Learning Inference Modelling D Yang*, J Fan, J Wang, W Hu, Fudan University Shanghai Cancer CenterShanghaiCN |
PO-GePV-T-247 | Energy Dependence of NanoDot Optically Stimulated Luminescence Dosimeters in the Superficial Radiation Therapy Energy Range Y Lee1,2*, S Davis1,2, R Tolakanahalli1,2, A Gutierrez1,2, (1) Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, FL, (2) Department of Radiation Oncology, Herbert Wertheim College of Medicine, Florida International University, Miami, Florida |
PO-GePV-T-287 | Evaluation of Dose Distribution Difference Between Plan and Delivery Using Kilovolt CT-Linac in Total Marrow and Lymphoid Irradiation DZ Jing*, D Deng, Y Xiong, J Gong, YC Wei, H Liu#, XY Wang#,Department of Radiation and Medical Oncology, Hubei Key Laboratory of Tumor Biological Behaviors,Hubei Cancer Clinical Study Center, Zhongnan Hospital of Wuhan University, Wuhan, China, 430071 |
PO-GePV-T-295 | Experimental Determination of Breast Skin Dose On Anthropomorphic Phantom Using VMAT and Field-In-Field Treatment Techniques A Cardona1*, JA Rojas-Lopez2, P Murina1, A Germanier3, C Venencia1, (1) Instituto Zunino, Cordoba, X, AR (2) Universidad Nacional de Cordoba, Cordoba, ,AR, (3) Unidad Estudios Fisicos, Ceprocor, Ministerio De Ciencia Y Tecnologia |
PO-GePV-T-395 | Phantom Evaluation of Dose Calculation Accuracy Comparing BrainLab and Eclipse Treatment Planning Systems (TPS) for Brain Stereotactic Radiosurgery (SRS) with Simulation and Film Dosimetry J Yoon*, H Jung, M Milano, K Usuki, S Hardy, D Zheng, University of Rochester, Rochester, NY |
PO-GePV-T-450 | High Resolution XACT Imaging for Precision Radiotherapy K Bjegovic1, S Wang1, R Liu 1, A Liu2*, L Xiang1, T Kim1, (1) University of California, Irvine, Irvine, CA, (2) City of Hope Medical Center, Duarte, CA |
SU-E-BRA-2 | Dosimetric Characterization of Patient Setup Uncertainty for Patients Treated with Craniospinal Irradiation Using a VMAT Approach K Osterman1, D Barbee1, J Teruel1, S Taneja1*, B Cooper1, J Zhang1, (1) NYU Langone Health, New York, NY |
SU-H300-IePD-F5-6 | Proton Range Shift Verification by Using Gamma Electron Vertex Imaging (GEVI) System in Spot Scanning Proton Therapy S. H. Kim1, Y. Ku2, J. Jung2, C. H. Kim2, J. H. Jeong1*, (1) Center for Proton Therapy, National Cancer Center, Goyang-si, Gyeonggi-do, KR, (2) Department of Nuclear Engineering, Hanyang University, Seoul, KR |