DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
Taxonomy: IM- Cone Beam CT: Development (New Technology and Techniques)
PO-GePV-I-1 | Comparing Effective Doses for Hip Imaging Using Cone Beam CT (CBCT) and Multidetector CT (MDCT) J Dave1, X Jiang2*, P Machado1, C Roth1, T Minch3, (1) Thomas Jefferson University, Philadelphia, PA, (2) Ohio State University, Columbus, OH, (3) Curvebeam, Hatfield, PA |
SU-E-201-2 | Cone-Beam CT From Complete Data Using Saddle Trajectories On a Mobile Robotic CBCT Scanner J Albrecht1,2*, S Rit3, P Steininger4, F Ginzinger4, P Huber4, I Messner4, M Kraihamer4, H Schmitz1, S Corradini1, C Belka1,5, C Kurz1, M Riboldi2, G Landry1, (1) Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany, DE, (2) Department of Medical Physics, Ludwig-Maximilians-Universitaet Muenchen (LMU Munich), Garching (Munich), Germany, DE, (3) Univ Lyon, INSA-Lyon, Universite Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69373, LYON, France, FR, (4) Research & Development, medPhoton GmbH, Salzburg, Austria, AT, (5) German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany, DE |
SU-F-BRC-6 | Patient-Specific Synthetic MRI Generation From CBCT for Image Guidance in Liver SBRT Z Zhang1*, Z Jiang2, K Lu3, F Yin4, L Ren5, (1) Duke University, Durham, NC, (2) Duke University, Durham, NC, (3) Duke University, Chapel Hill, NC, (4) Duke University Medical Center, Chapel Hill, NC, (5) University of Maryland, Baltimore, MD |
SU-H300-IePD-F8-6 | Perturbation-Based Quality Surrogate for Scatter Estimation and Parameter Optimization in Anti-Scatter Grid (ASG)-CBCT D Ruan1*, F Bayat2, C Altunbas2, (1) UCLA School of Medicine, Los Angeles, CA, (2) University of Colorado School of Medicine, Aurora, CO |
TH-C-201-2 | Catheter Tracking Using Gated Continuous-Sweep Limited Angle (CLA) Fluoroscopy M Wagner*, S Periyasamy, P Laeseke, A Raval, M Speidel, University of Wisconsin - Madison, Madison, WI |
TH-C-201-3 | Evaluating X-Ray Source Arrays for Tomography and Tomosynthesis in Lung Cancer Radiotherapy O Dillon*, R O'Brien, University of Sydney, Sydney, NSW, AU, |
TH-E-201-2 | Continuous Dual-Isocenter Imaging: Simultaneously Extending the Longitudinal and Lateral Intraoperative 3D CBCT Field-Of-View for Assessing Musculoskeletal Trauma T Reynolds1*, S Hatamikia2,3, O Dillon2, Y Ma4, A Kanawati5, J Stayman4, R O'Brien1, (1) University of Sydney, Sydney, AU, (2) Austrian Center for Medical Innovation and Technology, Wiener Neustadt, AUT, (3) Danube Private University, 3500 Krems an der Donau, AUT, (4) Johns Hopkins University, Balitmore, MD, (5) Westmead Hospital, Sydney, AU |