Click here to

DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.

Show All

Taxonomy: TH- External Beam- Photons: Computational dosimetry engines- Monte Carlo

MO-C930-IePD-F4-5Fast Monte Carlo Dose Calculation Tool for Varian Halcyon Using Virtual Source Models
J Castle1,2*, Q Chen2, X Feng1, (1) Carina Medical LLC, Lexington, KY, (2) University of Kentucky, Lexington, KY
MO-I430-BReP-F2-4Quantification of Gold Nanoparticle Radiosensitization On Prostate Cancer Combining Monte Carlo Simulations and the Local Effect Model
R Schmidt*, D Hara, N Dogan, J Shi, A Pollack, J Ford, University of Miami, Miami, FL
PO-GePV-T-264Implementation of a Static and Dynamic MLC Model in a GPU-Accelerated Monte Carlo Engine
E Brost, H Wan Chan Tseung, J Antolak*, Mayo Clinic, Rochester, MN
PO-GePV-T-267Validation of Breast Radiotherapy Planning Using PENELOPE Code
G de Souza Faes1*, V Botelho2, M Alva-Sanchez2, F Bruning3, T Pianoschi 2, A Marques da Silva4, (1) PREMUS, PUCRS, Porto Alegre, RS, BR, (2) Federal University Of Health Sciences Of Porto Alegre, UFCSPA, POrto Alegre, RS, BR, (3) Hospital Ernesto Gaertner, Curitiba, PR, BR, (4) Pontifical Catholic University of Rio Grande do Sul, PUCRS, Porto Alegre, RS, BR
PO-GePV-T-343Evaluation of the New Independent Dose Calculation SciMoCa as Patient-Specific Quality Assurance in the CyberKnife Treatment of Brain Metastases and Lung Cancer
K Sakai*1, 2, Y Nakajima1, 2, Y Suda2, S Kito2, Y Sato1, 3, K Yasui1, 2, Y Arai1, 2, T Takizawa1, 2, M Sato1, Y Fujita1, (1) Komazawa University, Setagaya-ku, Tokyo, Japan, (2) Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Tokyo, Bunkyo-Ku, Japan, (3) Tokyo Medical and Dental University, Bunkyo-Ku, Tokyo, Japan
PO-GePV-T-419A Deep Learning Dose Calculation Model for CyberKnife Circular Beams
H Li1, F Zhou1,2, B Liu1,2*, S Xu3, Q Wu4, (1) Image Processing Center, Beihang University, Beijing, CN (2) Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, CN (3) National Cancer Center/Cancer Hospital- Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, BJ, CN, (4) Duke University Medical Center, Durham, NC
SU-J-BRC-6Investigation of Computation Time and Storage Saving Using Generative Adversarial Network (GAN) Source Models for Dose Simulation of a Binary MLC Linac
M Shi1*, S Cui1, C Chuang1, O Oderinde2, N Kovalchuk1, K Bush1, M Surucu1, L Xing1, B Han1, (1) Stanford University, Palo Alto, CA, (2) RefleXion Medical, Hayward, CA
TU-I345-IePD-F4-4Commissioning and Validation of a Monte Carlo Algorithm for Spine Stereotactic Radiosurgery
C Knill*, R Sandhu, B Loughery, L Lin, R Halford, D Drake, M Snyder, Beaumont Health, Royal Oak, MI
WE-C930-IePD-F4-3Dosimetric Impact of Spinal Implant Hardware Material Selection Evaluated with Monte Carlo and Collapsed Cone Calculation Algorithms
J Andreozzi*, L Nardella, K Latifi, N D Tran, G Redler, H. Lee Moffitt Cancer Center, Tampa, FL
WE-G-206-6Optimization of Target Design and Dose Rates for FLASH-RT of An 18 MV Medical Linear Accelerator Model Via GEANT4 Monte Carlo Simulation
A Li1*, S.V. Kutsaev2, V Yu2, S Boucher2, K Sheng1, (1) UCLA Department of Radiation Oncology, Los Angeles, CA, David Geffen School of Medicine at UCLA (2) RadiaBeam, Santa Monica, CA

Share: