DISCLAIMER:
Entry of taxonomy/keywords during proffered abstract submission was optional.
Not all abstracts will appear in search results.
MO-C930-IePD-F8-5 | Effect of Tin Spectral Filtration On Organ and Effective Dose in CT Colonography and CT Lung Cancer Screening G Fong1*, A Skalsky2, F Dong1, B Herts1, D Nachand1, A Primak3, P Segars4, X Li1, (1) Imaging Institute, Cleveland Clinic, Cleveland, OH, (2) Cleveland State University, Cleveland, OH, (3) Siemens Medical Solutions USA, Inc., Cleveland, OH, (4) Duke University, Durham, NC |
MO-E115-IePD-F2-2 | On the Utilization of a Pseudo-Inverse Consistency Metric to Evaluate Deformable Dose Accumulation Error for MRI-Guide Adaptive Radiotherapy H Zhong*, J Garcia-Alvarez, K Kainz, X Li, Medical College of Wisconsin, Milwaukee, WI |
MO-E115-IePD-F6-3 | Retrospective Cardio-Respiratory Motion Corrected Dose Evaluation for the Left Ventricle and Left Ventricle Myocardium From Lung Radiation Therapy Treatments A Omidi1*, E Weiss2, J Wilson1,3, M Rosu-Bubulac2, (1) Department of Biomedical Engineering, School of Engineering, Virginia Commonwealth University, Richmond, VA, (2) Department of Radiation Oncology, School of Medicine, Virginia Commonwealth University, Richmond, VA, (3) Pauley Heart Center, School of medicine, Virginia Commonwealth University, Richmond, VA, |
MO-E115-IePD-F7-4 | Evaluating the Superficial Dose Enhancement of Brass Mesh Bolus for VMAT Postmastectomy Radiation T Keiper*, K Kisling, P Hua, R Manger, UC San Diego, La Jolla, CA |
MO-E115-IePD-F7-6 | Extracting Organ-Specific Radiobiological Parameters From Compiled Clinical Data for Reirradiation Planning of Head and Neck Cancer E Quashie, A Tai*, P Prior, M Awan, C Schultz, X Li, Medical College of Wisconsin, Milwaukee, WI |
MO-G-BRC-2 | Experimental and Monte Carlo Based Determination of Magnetic Field Correction Factors KB in 6 MV Photon Fields M Alissa1,2,D Czarnecki2, A A. Schoenfeld3*, R Kapsch4, S Frick4, K Zink1,2,5, (1) Institute of Medical Physics and Radiation Protection, University of Applied Sciences (THM), Giessen, Germany (2) Department of Radiotherapy and Radiation Oncology, University Medical Center Giessen and Marburg, Giessen, Germany (3) Sun Nuclear Corporation, 3275 Suntree Blvd, Melbourne, Florida, 32940 USA (4) Physikalisch-Technische Bundesanstalt (German national metrology institute) Braunschweig, Germany (5) Marburg Ionbeam Therapycenter (MIT), Marburg, Germany. |
MO-H345-IePD-F1-1 | Cumulative Dose Evaluation On TSET Patient Fem Using Cherenkov Imaging Y Zhu1*, W Zhong1, T Miao2, B Pogue3, T Zhu1, (1) University of Pennsylvania, Philadelphia, PA, (2) Yale University, New Heven, CT, (3) Department of Medical Physics, University of Wisconsin-Madison, Madison, WI |
MO-H345-IePD-F5-1 | Simultaneous Temporal and Dose Optimization for MLC Tracking: Cutting Dose Errors in Half L Mejnertsen1*, E Hewson1, J Booth2,3, P Keall1, (1) ACRF Image X Institute, University of Sydney Medical School, Sydney, NSW, Australia (2) Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW, Australia (3) School of Physics, University of Sydney, Sydney, NSW, Australia |
MO-H345-IePD-F6-2 | Rtdsm: An Open-Source Software for Dose-Surface Map Generation and Analysis H Patrick*, J Kildea, McGill University, Montreal, QCCA, |
MO-H345-IePD-F6-3 | Characterization of Fluoroscopy Radiation Dose Associated with the Administration of Y-90 Microspheres for Radioembolization Therapy X Nie*, K Recca, J Zhang, University of Kentucky, Lexington, KY |
MO-H345-IePD-F7-3 | A Comparison of In-House and Shared Knowledge-Based Planning (KBP) Models for Bilateral Head and Neck Treatment Planning O Trejo*, H Li, K Guida, The University of Kansas Cancer Center, Kansas City, KS |
MO-I430-BReP-F1-2 | Diagnostic Performance of Lung Cancer Screening On Low Dose CT C Read*, T Tailor, K Smith, M Cerullo, L Strickland, C Wang, B Tong, K Lafata, Duke University Medical Center, Durham, NC |
MO-I430-BReP-F1-3 | CT Dose Index Determination in Dose Modulation Prospectively Involving the Third-Generation Iterative Reconstruction and Noise Index A Scott*, Y Zhou, C Lee, E Eastman, Cedars-Sinai Medical Center, Los Angeles, CA |
MO-I430-BReP-F1-5 | Dose Assessment On the Use of Tin Spectral Filtration for CT Colonography G Fong1*, X Li1, N Obuchowski1, D Nachand1, F Dong1, A Primak2, W Karim1, B Herts1, (1) Cleveland Clinic, Cleveland, OH, (2) Siemens Medical Solutions USA, Inc., Cleveland, OH |
MO-I430-BReP-F2-1 | An Automated Solution to Presenting Dose Distributions of Radiotherapy in a Hospital Information System J Wu*, J Lin, A Pompos, D Sher, K Westover, R Timmerman, S Jiang, Y Yan, UT Southwestern Medical Center, Dallas, TX |
MO-I430-BReP-F3-4 | Robust Multi-Site Deep Learning-Based Dose Predictions for Volumetric Modulated Arc Therapy Using the MR-Linac G Tsekas*, G Bol, B Raaymakers, University Medical Center Utrecht, Utrecht, UtrechtNL, |
PO-GePV-I-1 | Comparing Effective Doses for Hip Imaging Using Cone Beam CT (CBCT) and Multidetector CT (MDCT) J Dave1, X Jiang2*, P Machado1, C Roth1, T Minch3, (1) Thomas Jefferson University, Philadelphia, PA, (2) Ohio State University, Columbus, OH, (3) Curvebeam, Hatfield, PA |
PO-GePV-I-47 | Development of a Web-Based Tool for the Estimation of Organ Doses in Pediatric and Adult Chest CT Examinations J Damilakis*, J Stratakis, M Myronakis, |
PO-GePV-I-50 | The Effect of Beam Overlapping in Dual-Energy Volume CT Scans and Single-Energy Helical Scans N Correa*, I Barreto, M Arreola, University of Florida, Gainesville, FL |
PO-GePV-I-56 | Development of An Ultra-Low Dose Computed Tomography Protocol for Detection of Inhaled Foreign Bodies in Pediatric Patients C Kofler*, I Reiser, E Marshall, Z Lu, K Feinstein, M Zaritzky, Department of Radiology, The University of Chicago, Chicago, IL |
PO-GePV-I-71 | CT-Dose: Software Interface to Calculate Dose to Organ in Medical Imaging S. Morato1,2,3*, R. Miro3, B. Juste3, S. Oliver3, J. Vijande1,2,4, F. Ballester1,4, G. Verdu3, A. Santos5, Matthew M. Mille6, (1) Departamento de Fisica Atomica, Molecular y Nuclear, Universitat de Valencia (UV), Burjassot, ES, (2) Instituto de Fisica Corpuscular, IFIC (UV/CSIC), Burjassot, ES, (3) Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politecnica de Valencia, Valencia, ES, (4) Unidad Mixta de Investigacion en Radiofisica e Instrumentacion Nuclear en Medicina (IRIMED), Instituto de Investigacion Sanitaria La Fe (IIS/La Fe)/Universitat de Valencia (UV), Valencia, ES, (5) Servicio De Radiofisica. Consorci Hospitalari Provincial De Castello, Castellon, ES. (6) Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD 20850, United States. |
PO-GePV-M-4 | Domain Knowledge Driven 3D Dose Prediction Using Moment-Based Loss Function G Jhanwar1*, N Dahiya2, P Ghahremani3, M Zarepisheh4, S Nadeem5, (1) Memorial Sloan Kettering Cancer Center, New York, NY, (2) Georgia Institute Of Technology, ,,(3) Memorial Sloan Kettering Cancer Center, ,,(4) Memorial Sloan Kettering, New York, NY, (5) Memorial Sloan Kettering Cancer Center, New York, NY |
PO-GePV-M-22 | Personalization of Patient Specific Radiation Dose and Dose Fractionation Using Volumetric Tumor Dynamics H Enderling1*, M Zahid1, E Moros1, J Caudell1, A Mohamed2, C Fuller2, (1) H. Lee Moffitt Cancer Center & Research Institute, Tampa, FL,(2) UT MD Anderson Cancer Center, Houston, TX, (6) UT MD Anderson Cancer Center, Houston, TX |
PO-GePV-M-23 | SliCERR: An Extension for 3D Slicer to Execute CERR Analysis Routines E LoCastro1*, H Veeraraghavan2, T Kapur3, A Iyer4, C Pinter5, G Sharp6, J Deasy7, A Apte8, (1) Memorial Sloan Kettering Cancer Center, New York, New York, (2) Memorial Sloan Kettering Cancer Center, New York, NY, (3) Harvard Medical School, Boston, MA, (4) Memorial Sloan Kettering Cancer Center, New York, NY, (5) Queen's University, Kingston, ON, CA, (6) Massachusetts General Hospital, Beverly, MA, (7) Memorial Sloan Kettering Cancer Center, New York, NY, (8) Memorial Sloan-Kettering Cancer Center, Maywood, NJ |
PO-GePV-M-44 | Active Learning for Deep Learning Dose Prediction as a Radiotherapy QA Tool in Radiotherapy M Huet Dastarac*, A Barragan Montero, J Lee, Universite Catholique de Louvain, Brussels, BE |
PO-GePV-M-49 | Evaluating the Use of Software Parallelism for DVH Calculations W Sleeman, P Turner, P Bose, S Srinivasan, P Ghosh, J Palta, R Kapoor*, Virginia Commonwealth University, Richmond, VA |
PO-GePV-M-71 | A Novel Dose-Volume Constraint to Reduce Toxicity Rates of the Parotid Glands for Head-And-Neck Cancer Patients H Choun1*, J Son2, S Kang2, H Jin2, E Yoon1, H Wu1; 2, J Park1;2 (1) Seoul National University, Seoul, KR, (2) Seoul National University Hospital, Seoul,KR |
PO-GePV-M-77 | 3D Surface Imaging of Pleural Cavity for Light Fluence Modeling During PDT D Sourvanos, H Sun, J Fiorellini, K Cengel, T Zhu*, University of Pennsylvania, Philadelphia, PA |
PO-GePV-M-78 | A Real time IR Navigation System for Pleural Photodynamic therapy H Sun*, M Kim, K Cengel, T Zhu, University of Pennsylvania, Philadelphia, PA |
PO-GePV-M-112 | Three-Dimensional Dose Super-Resolution Using Implicit Neural Representation V Vasudevan1*, O Pastor-Serrano2,4, C Huang3, C Chuang4, Z Perko2, P Dong4, L Xing4, (1) Stanford University, Stanford, CA, (2) Delft University of Technology, Delft, NL, (3) Stanford University, Stanford, CA, (4) Stanford University School of Medicine, Stanford, CA, |
PO-GePV-M-119 | DVH Distortion in Deformably Propagated Dose Grids - a Practical Challenge for Adaptive Radiotherapy J Kipritidis1*, A Quinn1, T Morgas2, S Kuckertz3, N Papenberg3, S Heldmann3, T Coradi2, F Franco2, J Kieselmann2, C Huang2, J Booth1, (1) Northern Sydney Cancer Centre, Sydney, NSW, AU, (2) Varian Medical Systems, Palo Alto, CA, (3) Fraunhofer MEVIS, Lubeck, DE |
PO-GePV-M-121 | The Dosimetric Performance of Online Adaptive Radiotherapy Based On CT-LINAC for Cervical Cancer DZ Jiang*, CX Yang*, ZJ Mei, J Gong, H Liu#, H Qiu#, XY Wang#, Department of Radiation and Medical Oncology, Hubei Key Laboratory of Tumor Biological Behaviors,Hubei Cancer Clinical Study Center, Zhongnan Hospital of Wuhan University, Wuhan, China, 430071 |
PO-GePV-M-127 | Deep Learning for MRI-Generated Synthetic CT: Dosimetric Evaluation for RT Planning in Head and Neck Cancers JT Antunes1*, D Pittock1, P Jacobs1, AS Nelson1, J Piper1, T Young2,3, S Deshpande3,4 (1) MIM Software Inc, Cleveland, OH, (2) Institute of Medical Physics, School of Physics, University of Sydney, Australia, (3) Liverpool And Macarthur Hospital, Liverpool, Australia, (4) South Western Sydney Clinical School, University of New South Wales, Sydney, Australia |
PO-GePV-M-131 | Evaluation of a Real-Time Method for Motion-Induced Dose Error Reporting for Pancreas Stereotactic Body Radiotherapy M Gargett1,2*, A Ahmed1, A Briggs1, T Ravkilde3, S Skouboe4, P Poulsen4,5,6, G Hruby1,7, A Kneebone1,7, P Keall8, J Booth1,9, (1) Northern Sydney Cancer Centre, Royal North Shore Hospital, AU, (2) School of Health Sciences, Faculty of Medicine and Health, University of Sydney, AU, (3) Department of Medical Physics, Aarhus University Hospital, DK, (4) Danish Centre for Particle Therapy, Aarhus University Hospital, DK, (5) Department of Oncology, Aarhus University Hospital, DK, (6) Department of Clinical Medicine, Aarhus University, DK, (7) Northern Clinical School, University of Sydney, AU, (8) ACRF Image X Institute, University of Sydney, AU, (9) Institute of Medical Physics, School of Physics, University of Sydney, AU |
PO-GePV-M-167 | Feasibility Study of Quantifying the Dosimetric Discrepancies of Planned Dose in Comparison to Delivered Dose Utilizing Daily Cone-Beam Computed Tomography (CBCT) T Cuthbert1*, S Stathakis2, P Mavroidis3, N Papanikolaou4, W Jones5, (1) UT Health Sciences Center, San Antonio, TX, (2) Mays Cancer Center - MD Anderson Cancer Center, San Antonio, TX, (3) University of North Carolina, Chapel Hill, NC, (4) University of Texas HSC SA, San Antonio, TX, (5) University of Texas HSC San Antonio, San Antonio, TX |
PO-GePV-M-230 | Dosimetric Evaluation of Respiratory Gating On a 0.35 T Magnetic Resonance Guided Radiotherapy Linac J Charters*, Y Abdulkadir, D O'Connell, Y Yang, J Lamb, University of California, Los Angeles, Los Angeles, CA |
PO-GePV-M-233 | Impact of 0.35 T Magnetic Field On Surface Dose I Das1*, P Yadav2, (1) Northwestern University Feinberg School of Medicine, Chicago, IL, (2) Northwestern University Feinberg School of Medicine, Chicago, IL |
PO-GePV-M-322 | Deep Learning Based Patient-Specific Auto-Segmentation of Target and Organs at Risk On Daily Fan-Beam CT Images Y Chen*, S Butler, L Yu, Y Zhou, L Shen, N Kovalchuk, H Bagshaw, M Gensheimer, L Xing, B Han, Stanford University School of Medicine, Stanford, CA |
PO-GePV-M-351 | Three-Dimensional Dose-Function Data-Based Deep Convolutional Neural Network for Predicting Pulmonary Toxicity After Radiotherapy for Lung Cancer Y Fujita1*, Y Nakajima1, D Kawahara2, T Kimura3, T Yamamoto4, (1) Komazawa University, Tokyo, JP, (2) Hiroshima University, Hiroshima, JP, (3) Kochi University, Kochi, JP, (4) UC Davis School of Medicine, Sacramento, CA |
PO-GePV-T-58 | Better Identification of Dose Constraints for Use in HDR in the Treatment of Locally Advanced Cervix Cancer S Choudrie*, R Crilly, J Kahn, Oregon Health & Science Univ, Portland, OR |
PO-GePV-T-64 | Dosimetric Evaluation of Plastic Scintillation Detector for Skin Collimation in Electron Beam Radiation Therapy K Yang*, S Sharma, A Ju, East Carolina University, Greenville, NC |
PO-GePV-T-98 | Simulating Clinical Protocol Accrual in the Radiotherapy Outcomes Estimator (ROE) A Iyer*, E Yorke, J Shin, A Apte, A Rimner, A Wu, M Thor, J Deasy, D Gomez, A Jackson, Memorial Sloan Kettering Cancer Center, New York, NY |
PO-GePV-T-115 | NTCP Modeling of Dysphagia 12 Months After Radiotherapy for Oropharyngeal Cancer Using the EAT10, CTCAE and PRO-QoL Scoring Systems A Tzikas1*, E Lavdas2, D Kehayas3, R Amdur4, W Mendenhall5, N Sheets6, S Stathakis7, R Green8, L Marks9, S Das10, B Chera11, P Mavroidis12, (1) University Of West Attica, Department Of Biomedical Sciences, Athens, Greece, (2) University of West Attica, Athens, Greece, (3) University Of West Attica, Athens, Greece, (4) University of Florida Hospitals, Gainesville, FL, (5) University of Florida, Gainesville, FL, (6) Duke University, Raleigh, NC, (7) Mays Cancer Center - MD Anderson Cancer Center, San Antonio, TX, (8) UNC at Chapel Hill, NC, (9) University of North Carolina at Chapel Hill, Chapel Hill, NC, (10) University of North Carolina, Chapel Hill, NC, (11) UNC at Chapel Hill, NC, (12) University of North Carolina, Chapel Hill, NC |
PO-GePV-T-119 | Pattern of Treatment and Outcome for Esophageal Adenocarcinoma in the United States: Longitudinal Analysis of a Large Hospital Based Registry A Dey1, T Biswas2, T Podder2*, (1) University of Akron, Akron, OH, (2) University Hospitals Seidman Cancer Center, Cleveland, OH |
PO-GePV-T-134 | Implementation of a Track-Repeating Fast Monte Carlo Method for the MD Anderson Proton Therapy Center II Q Wang1, 2*, F Poenisch2, U Titt2, R Mohan2, P Yepes1, 2, (1) Rice University, Houston, TX, (2) MD Anderson Cancer Center, Houston, TX |
PO-GePV-T-136 | Neutron Ambient Dose From Proton Irradiation of ICRU Tissue Calculated Via Monte Carlo Simulation A Gearhardt*, Y Chen, S Ahmad, M Newpower, University of Oklahoma Health Sciences Center, Oklahoma City, OK |
PO-GePV-T-164 | Assessment of Fetal Dose During Breast Radiotherapy Using a 3DCRT, IMRT, and Proton PBS Approach S Domal1*, F Giap2, P Johnson2, M Artz2, K Kirby2, C Williams2, W Bolch1, (1) University of Florida, Gainesville, FL, (2) University of Florida Health Proton Therapy Institute, Jacksonville, FL, |
PO-GePV-T-175 | Patient-Specific Duodenal Hydrogel Spacer as a Dosimetric Buffer for Proton Therapy for Locally Advanced Pancreatic Cancer D Han1*, H Hooshangnejad 2, J Jatczak3, W Yao4, J Xu5, K Ding6, (1) University of Maryland, Baltimore, MD, (2) Johns Hopkins university, Baltimore, MD, (3) University Of Maryland, (4) University of Maryland School of Medicine, Baltimore, MD, (5) University of Maryland, Baltimore, MD, (6) Johns Hopkins University, Baltimore, MD |
PO-GePV-T-197 | A Clinically Relevant Online Patient QA Solution for Adaptive Radiation Therapy with Daily CT Scans and EPID-Based in Vivo Dosimetry: A Feasible Study On Rectal Cancer L Chen*, J Wang, B Feng, L Yu, j zhao, W Hu, Z Zhang, Fudan University Shanghai Cancer Center, Shanghai, ShanghaiCN, |
PO-GePV-T-207 | Radiation Dose Tolerance of a Medtronic Deep Brain Stimulator Based On OSLD Measurement M Klash1*, S Klash2, E Mcclelland3, L Brennan4, J Grubic5, (1) KSEC, Belmont, Ohio, (2) VAPHS, Pittsburgh, PA, (3) VAPHS, Pittsburgh, PA, (4) VAPHS, Pittsburgh, PA, (5) VAPHS, Pittsburgh, PA |
PO-GePV-T-215 | A Practical Workflow to Determine Patient-Specific Critical Organ Dose Constraints Considering Organ-Specific Radiobiological Effect for Reirradiation Planning A Tai*, E Quashie, K Kainz, E Paulson, E Gore, J Bovi, M Awan, M Straza, X Li, Medical College of Wisconsin, Milwaukee, WI |
PO-GePV-T-262 | Learning DVH Criteria in Radiation Therapy Treatment Planning F Ahmadi*, T McNutt, K Ghobadi, Johns Hopkins University, Baltimore, MD |
PO-GePV-T-278 | Free Breathing Or Breath Hold for Pancreas Treatment Planning? T Lin*, C Ma, Fox Chase Cancer Center, 333 Cottman Ave., Philadelphia, PA 19111, USA |
PO-GePV-T-282 | Evaluation of VMAT & IMRT Planning Strategies for Advanced Prostate Cancer Patients with Bilateral Hip Prostheses J Xu*, T Cosely, T Bouton, B Zhang, D Han, J Zhou, S Chen, University of Maryland School of Medicine, Baltimore, MD |
PO-GePV-T-284 | Skin Dose Evaluation From Three Different IMRT Planning Technique On Beast Cancer Radiotherapy R He*, J Martinez, C Yang, University of Mississippi Medical Center, Jackson, MS |
PO-GePV-T-285 | A Study to Evaluate Optimal Energy Through Different Combination of Energy in Oesophageal Intensity Modulated Radiotherapy HRIDYA V T1,2*, D Khanna1, Aswathi Raj1,2, Sathish P2, Mohandass P3, (1) Karunya Institute of Technology and Sciences, Coimbatore, TN, IN, (2) Aster MIMS,Calicut ,Kerala,IN, (3) Fortis Hospital, Mohali, PB, IN |
PO-GePV-T-309 | Impact of CT-To-Density Table On Plan Quality C Yan*, Cleveland Clinic, Independence, OH |
PO-GePV-T-313 | Limited Dataset Transfer Learning for Deep Learning Dose Prediction On Head and Neck Cancer Patients Treated with Involved Nodal Radiation Therapy Using Artificial Intelligence-Based Radiomics (INRT-AIR) H Wang*, M Lin, D Sher, S Jiang, D Nguyen, UT Southwestern Medical Center, Dallas, TX |
PO-GePV-T-337 | Extending the Lifetime of Optically Stimulated Luminescent Dosimeters for Use in Output Checks at IROC- Houston H Scott1*, P Alvarez1, R Sun1, R Howell1, A Riegel2, S Kry1, (1) UT MD Anderson Cancer Center, Houston, TX, (2) Northwell Health, Lake Success, NY |
PO-GePV-T-394 | Analysis of Dose Drop Off Distance From Planning Target Volume Edge to 50% for Small Volume Tumors with Different Techniques Aswathi Raj1,2*, D Khanna1, HRIDYA V T 1,2, Mohandass P3, Sathish P2, (1) Karunya Institute of Technology and Sciences, Coimbatore, TN, IN, (2) Aster MIMS,Calicut ,Kerala,IN (3) Fortis Hospital, Mohali, PB, IN. |
PO-GePV-T-397 | Standardized Open-Source Volume Calculations for Small Voxelized Volumes R Cardan1*, R Popple2, (1) UAB University of Alabama, Birmingham, Birmingham, AL, (2) University of Alabama Birmingham, Birmingham, AL |
PO-GePV-T-413 | Calculated Target Dose Differences for Brain Stereotactic Radiosurgery (SRS) Between Two Advanced Dose Algorithms D Zheng*, H Jung, M Milano, K Usuki, S Hardy, S Tanny, J Yoon, University of Rochester, Rochester, NY |
PO-GePV-T-419 | A Deep Learning Dose Calculation Model for CyberKnife Circular Beams H Li1, F Zhou1,2, B Liu1,2*, S Xu3, Q Wu4, (1) Image Processing Center, Beihang University, Beijing, CN (2) Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, CN (3) National Cancer Center/Cancer Hospital- Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, BJ, CN, (4) Duke University Medical Center, Durham, NC |
SU-E-BRB-1 | Adaptation of Dose Prediction DenseNet for Prostate Cancer Patients Treated with Different Beam Modes Using Transfer Learning J Fu1*, Z Wang2, J Lewis3, X Qi2, (1) Stanford Radiation Oncology, Stanford, CA, (2) UCLA School of Medicine, Los Angeles, CA (3) Cedars-Sinai Medical Center, Pacific Palisades, CA |
SU-F-206-5 | Deep Learning Dose Prediction as a Tool to Evaluate Treatment Complications Based On NTCP Models C Draguet1,2*, A Barragan Montero1, P Populaire2,3, G Defraene2, M Thomas2,3, K Haustermans2,3, J Lee1, E Sterpin1,2, (1) UCLouvain - Institut de Recherche Experimentale et Clinique - Molecular Imaging Radiotherapy and Oncology (MIRO), Brussels, BE, (2) KULeuven - Department of Oncology - Laboratory of Experimental Radiotherapy, Leuven, BE, (3) University Hospital Leuven, Department of Radiation Oncology, Leuven, BE |
SU-F-206-8 | Quantifying the Impact of Deformable Dose Accumulation Using Voxel-Level Dose-Response Analysis for Non-Small Cell Lung Cancer Y He*, G Cazoulat, C Wu, L Almodovar-Abreu, E Mccollum, B Rigaud, P Balter, J Pollard-Larkin, D Rhee, L Court, Z Liao, R Mohan, K Brock, The University of Texas MD Anderson Cancer Center, Houston, TX |
SU-F-BRA-4 | How Well Does the IROC H&N Phantom Serve as a Surrogate for Different Anatomical Sites? F Brooks1,2*, M Glenn3, C Peterson1, C Nelson1, C Clark4, J Pollard-Larkin1, R Howell1,2, S Kry1,2, (1) MD Anderson Cancer Center, Houston, TX, (2) IROC Houston QA Center, Houston, TX, (3) University of Washington, Seattle, WA, (4) UCLH, London, SRY, GB, |
SU-F-BRC-1 | Evaluation of Variables Predicting Pulmonary Function Test (PFT) Changes for Lung Cancer Patients Treated On a Prospective 4DCT-Ventilation Functional Avoidance Clinical Trial N Ghassemi1*, R Castillo2, E Castillo3, B Jones4, M Miften5, B Kavanagh6, B Lu7, M Werner-Wasik8, R Miller9, J Barta10, I Grills11, T Guerrero12, C Rusthoven13, Y Vinogradskiy14, (1) Thomas Jefferson University Hospital, Philadelphia, PA, (2) Emory University, Atlanta, GA, (3) University of Texas at Austin, Austin, TX, (4) University of Colorado School of Medicine, Aurora, CO, (5) University of Colorado School of Medicine, Aurora, CO, (6) University of Colorado School of Medicine, Aurora, CO, (7) University of Florida, Gainesville, FL, (8) Sidney Kimmel Cancer Center at Thomas Jefferson University Hospital, Philadelphia, ,(9) Thomas Jefferson University, ,,(10) Thomas Jefferson University, ,,(11) Beaumont Health System, Royal Oak, MI, (12) ,Royal Oak, MI, (13) University Of Colorado Anschutz Medical Campus, ,,(14) Thomas Jefferson University, Philadelphia, PA |
SU-H300-IePD-F4-4 | Development of a Multi-Domain Neural Network (MDNN) for Survival Prediction in Liver Metastases Patients Treated with Stereotactic Body Radiotherapy (SBRT) A Amini*, T Arsenault, A Baydoun, K Nam, T Biswas, T Podder, University Hospitals CLeveland Medical Center, Cleveland, OH |
SU-H300-IePD-F7-5 | A Deep Convolutional Neural Network Based Dose Engine for Seed Implant Brachytherapy T Xiong1, L Geng1, F Zhou2,3, B Liu2,3*, Q Wu4, (1) School of Physics, Beihang University, Beijing, CN (2) Image Processing Center, Beihang University, Beijing, CN (3) Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, CN (4) Duke University Medical Center, Durham, NC |
SU-H330-IePD-F7-1 | A Knowledge-Based Machine Learning Model for DVH Prediction in HDR Brachytherapy Z Li1, B Zhou1*,Q Zhu1, Z Li1, J Fu1, Z Yang2, (1) Shanghai Sixth People's Hospital, Shanghai, Shanghai, CN, (2) Duke University, Durham, NC |
SU-H430-IePD-F5-3 | A Sensitivity Analysis On the Relationship Between Dose and Overlap Metrics for Head & Neck Normal Tissues B Marquez1,2*, C Owens1,2, K Huang1,2, M El Basha1,2, R Mumme2, C Nguyen2, C Peterson1,2, D Fuentes1,2, T Whitaker1,2, T Netherton1,2, L Court1,2,(1) University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX, (2) MD Anderson Cancer Center, Houston, TX |
SU-J-BRC-1 | AI-Dose Predictor for Secondary Dose Calculation for a Novel Compensator-Based IMRT System for Low- and Middle-Income Countries K Oh1,2*, M Gronberg2, S Gay2, A Olanrewaju2, B Sengupta1, T Netherton2, C Cardenas3, L Court2, E Ford1, (1) University of Washington, Seattle, WA, (2) UT MD Anderson Cancer Center, Houston, TX, (3) The University of Alabama at Birmingham, Birmingham, AL |
SU-J-BRC-4 | An Investigation of the Transferability of Deep-Learning Based Head and Neck Dose Prediction Model Among Different Institutions Y Chang*, B Teo, T Li, R McBeth, University of Pennsylvania, Philadelphia, PA |
SU-K-201-4 | Size Specific Alert Thresholds for Individualized Patient Dose Monitoring in CT B Hurley*, C Smitherman, T Petrone, Petrone Associates, LLC, New York, NY |
SU-K-206-2 | Analytical Modeling of Intertrack Interaction in Ultra-High Dose Rate (FLASH) Radiotherapy A Baikalov1,2,3*, R Abolfath4, R Mohan4, J J Wilkens2, S Bartzsch2,3, (1) Technical University of Munich, Garching, DE, (2) Klinikum rechts der Isar, Munich, DE, (3) Helmholtz Zentrum Muenchen GmbH, German Research Center for Environmental Health, Neuherberg, DE, (4) UT MD Anderson Cancer Center, Houston, TX |
TH-B-BRA-4 | Examination of Stability and Heat Transfer Effects of a Graphite Probe Calorimeter N MacKay1*, F Keszti1, J Seuntjens2, A Sarfehnia3, J Renaud4, (1) McGill University, Montreal, QC, CA, (2) University Health Network, Toronto, ON, (3) Sunnybrook Health Science Center, Toronto, ON, CA, (4) National Research Council Canada, Ottawa, ON |
TH-B-BRA-5 | Investigating Dosimetry for Individual Proton Beamlets N Nelson1*, W Culberson1, D Hyer2, L Bennett2, T Geoghegan2, K Patwardhan2, B Smith2, R Flynn2, J Yu3, A Gutierrez3, P Hill4, (1) University of Wisconsin - Madison, School of Medicine and Public Health, Department of Medical Physics, Madison, WI, USA, (2) University of Iowa, Department of Radiation Oncology, Iowa City, IA, USA, (3) Miami Cancer Institute, Department of Radiation Oncology, Miami, FL, USA, (4) University of Wisconsin - Madison, School of Medicine and Public Health, Department of Human Oncology, Madison, WI, USA |
TH-D-207-6 | Texture Transformer Super-Resolution (TTSR) for Patient CT Images S Zhou1*, L Yu2, M Jin1, (1) University of Texas at Arlington, Arlington, TX, (2) Mayo Clinic, Rochester, MN |
TH-D-BRC-5 | Normal Tissue Complication Modeling for Radiation-Induced Lymphopenia After Abdominal Radiotherapy S Kim1*, H Byun2, W Sung1, ((1) Department of Biomedical Engineering and Biomedicine & Health Science, College of Medicine, The Catholic University of Korea, Seoul, KR (2) Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, KR |
TU-D1000-IePD-F2-2 | Introducing An Isotoxic Paradigm for Delivery of Ultra-High Doses to Oligometastatic Disease Using Ethos Online Adaptive Radiotherapy G Redler1*, H Musunuru2, R Katipally3, C Lynch3, N Nasser1,4, A Olson2, G Gan5, J Luke2, S Chmura3, (1) H. Lee Moffitt Cancer Center, (2) University of Pittsburgh Medical Center, (3) University Of Chicago Medical Center, (4) University of South Florida, (5) University Of Kansas Cancer Center |
TU-D1000-IePD-F2-5 | Adaptive Radiotherapy Via Deep Learning-Based Quantitative Cone-Beam CT Imaging L Wan1*, H Wu2, S Xu3, B Sun4, W Zhao5, (1) Beihang University, Beijing, BJ, CN (2) Beijing Cancer Hospital, Beijing, BJ, CN, (3) National Cancer Center/Cancer Hospital- Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, BJ, CN, (4) Beihang University,Beijing, BJ, CN(5) Beihang University, Beijing, BJ, CN |
TU-D1000-IePD-F4-3 | A 3D Dosimetric Data-Driven Multipath Network for Outcome Prediction in Early-Stage Non-Small Cell Lung Cancer Patients Treated with Stereotactic Body Radiotherapy T Arsenault1*, A Amini1, B George2, S Bhat2, L Bailey2, P Vempati4, B Young4, C Towe1, P Linden1, Y Sun2, N Zaorsky1, D Spratt4, R Muzic3, T Biswas4, T Podder4, (1) University Hospitals Cleveland Medical Center, Cleveland, OH, (2) Case Western Reserve University, School Of Medicine, (3) Case Western Reserve University, Department of Biomedical Engineering, (4) Seidman Cancer Center /Uh Cleveland & CWRU, OH, Cleveland, OH, |
TU-D1000-IePD-F5-5 | Daily Dose Assessment On Organ Variation and Target Coverage for Post-Operative Prostate Cancer Patients S Lo*, B Laughlin, T DeWees, M Beckett, K Tinnon, C Vargas, S Schild, N Yu, J Rwigema, S Keole, W Wong, Y Rong, Mayo Clinic Arizona, Phoenix, AZ |
TU-D1000-IePD-F8-3 | Dose-Reduced Kidney Stone CT Protocol Optimized with Size-Specific Dose Estimate S Deng1,2*, A Kulkarni1,2, N Harris1,2, L Zimmermann1,2, R Al Helo1,2, D Jordan1,2,3, (1) Dept of Radiology, University Hospital Cleveland Medical Center, Cleveland, OH, (2) Radiation Safety, University Hospitals Cleveland Medical Center, Cleveland, OH, (3) Dept. of Radiology, Case Western Reserve University, Cleveland, Ohio |
TU-D1030-IePD-F7-4 | Independent Beam Modeling for the RefleXion X1 System M Chen, J Tan, G Gibbard, Y Park, T Zhuang, M Lin, K Wang, X Jia, B Cai, W Lu*, University of Texas Southwestern Medical Center, Dallas, TX |
TU-D930-IePD-F4-4 | Benchmarking Publicly Available Knowledge-Based Planning Models with An In-House Trained Model J Zhang*, J Wolf, K Luca, O Kayode, J Bradley, X Yang, T Liu, J Roper, Emory University, Atlanta, GA |
TU-F115-IePD-F6-3 | An Estimate of Fetal Dose From Permanent Cs-131 Brachytherapy Implants in the Brain A Turner1*, C Ferreira2, (1) GT Medical Technologies, Inc, Phoenix, AZ, (2) University of Minnesota, Minneapolis, MN |
TU-J430-BReP-F3-4 | Motion Effects in Cardiac Ablation Radiotherapy J Marcel1, R Trevillian1*, N Yegya-raman1, L Yin1, Z Zhang1, H Chen1, S Feigenberg1, L Dong1, J Arkles2, B Teo1, K Cengel1, W Zou1, (1) University of Pennsylvania, Department of Radiation Oncology, Philadelphia, PA, (2) University of Pennsylvania, Department of Cardiology, Philadelphia, PA |
WE-C930-IePD-F3-2 | Estimates of Fetal Dose with the Mevion S250i Proton Therapy System with HYPERSCAN K M Hopfensperger, A Paxton, V Sarkar, F Su, R G Price, B J Salter, S St. James*, University of Utah - Huntsman Cancer Institute, Salt Lake City, UT |
WE-C930-IePD-F3-4 | A GPU-Accelerated Monte Carlo Dose Computation Engine for Precision Small Animal Radiotherapy Z Liu, Y Yang*, University of Science and Technology of China, Hefei, China |
WE-C930-IePD-F6-3 | AI-Assisted Clinical Decision Making (CDM) for Radiosurgery of Brain Metastases Using Three-Path Three-Dimensional CNN Y Cao*, D Kunaprayoon, J Xu, L Ren, University of Maryland, Baltimore, MD |
WE-C930-IePD-F6-6 | Predict Voxel-Wise Active Bone Marrow Loss of Anal Cancer Patients Treated with Chemoradiation Using 3D U-Net Deep Learning of Post-Radiotherapy PET Images Y Yue*, Y Le, O Ishaq, T Lautenschlaeger, Indiana University School of Medicine, Indianapolis, Indiana |
WE-E-202-2 | Impact of Image Registration Type and Quality On Post-Radioembolization Y90 PET/CTdosimetry A Gopal*, O Siddiqui, J Molotoris, M Guerrero, University of Maryland School of Medicine, Baltimore, MD |
WE-F-206-5 | Quantifying Reactive Species and Oxygen Consumed in FLASH Radiotherapy in Vitro to Assess Mechanisms of Tissue Damage Reduction J Sunnerberg1*, A Petusseau1, M Rahman1, X Cao1, P Bruza1, S Vinogradov2, B Pogue1,3, (1) Dartmouth College, Hanover, NH, (2) University Of Pennsylvania, Philadelphia, PA (3) University of Wisconsin-Madison, Madison, WI |